SunStat™ Thermostat
ETL Listed in U.S. and Canada

SunStat™ (non-programmable)
Model# 500675

The most obvious change in our new non-programmable control is that it is now digital. However, behind the digital face of our new SunStat are nearly all of the same features as our new programmable model:

  • Dual-Voltage 120/240VAC makes it easy to stock and easy to install.
  • Built-in GFCI means safety and no need for a GFCI breaker.
  • Built-in 15-amp relay for control of up to 150 sq. ft. at 120V or 300 sq. ft. at 240V.
  • Drives up to 10 SunStat™ Relays for control of up to 1650 sq. ft. at 120V or 3300 sq. ft. at 240V.
  • Remote Control option allows control by home automation system.
  • Setback button for quick temperature adjustments.
  • Keyboard Lockout feature prevents unauthorized changes.
  • Floor and Air sensing modes.
SunStat™ Pro Thermostat
ETL Listed in U.S. and Canada

SunStat™ Pro (programmable)
Model# 500670

The new SunStat Pro is, by far, the most sophisticated electric floor warming control available. It incorporates an amazing variety of function and elegance into one thermostat:

  • All the features of the standard SunStat, plus…
  • 5/1/1 Day Programming allows for energy saving control.
  • 4 Preset Program Schedules for easy setup.
  • 1 User Program Schedule for customized programming.
  • SmartStart™ Technology intelligently adjust when the floor warming system turns on to ensure the floor is warm at your scheduled time.
  • Usage Monitor shows the hours of system operation.
SunStat™ Thermostat
ETL Listed in U.S. and Canada

SunStat™ Relay (sub-control)
Model# 500680

If a mat or cable system requires more than 15 amps, we recommend installing SunStat Relays. Relays connect directly to SunStat thermostats for simple, elegant control of larger systems. SunStat Relays don’t require a special “master thermostat”, as before.

It’s possible to control over 1500 sq.ft. of electric floor warming using 120 VAC and over 3,000 sq.ft. using 240 VAC floor warming mats or cables. First, find the amp draw for each SunTouch, UnderFloor or WarmWire product in this catalog or in manuals. Then determine how many can connect to each relay. Up to ten 15-amp Relays can connect to one SunStat. Ten Relays, plus the internal relay in the SunStat, provide a total capacity of 165 amps! Each Relay should be connected to individual 20-amp breakers, as shown in the owner's manual.

  • Dual-Voltage 120/240VAC makes it easy to stock and easy to install.
  • Built-in GFCI means safety and no need for a GFCI breaker.
  • Built-in 15-amp relay for control of up to 150 sq. ft. at 120V or 300 sq. ft. at 240V.
  • Heating Indicator and on/off switch for added control.

Document Downloads

SunStat™ manual thumbnail

SunStat™
Owners manual

Size: 674 KB
Type: Adobe® PDF®
SunStat™ Pro manual thumbnail

SunStat™ Pro
Owners manual

Size: 1.14 MB
Type: Adobe® PDF®
SunStat™ Dial manual thumbnail

SunStat™ Dial
Owners manual

Size: 317 KB
Type: Adobe® PDF®
REET Test & Report Procedures

SunStat™ Relay
Owners manual

Size: 336 KB
Type: Adobe® PDF®
Get Adobe® Reader®
You will need Adobe® Reader® to view PDF® documents.
"Adobe" and "the Adobe logo", "Reader" and "PDF" are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries.